Email Alert  RSS
应用技术

不同类型杂散电流对管道干扰波动规律特征

展开
  • 1国家石油天然气管网集团科学技术研究总院分公司; 2国家管网集团北方管道公司天津输油气分公司; 3国家管网集团北方管道公司中原天然气有限责任公司; 4国家管网集团北方管道沧州输油气分公司
徐承伟(1982-),博士,高级工程师,主要从事油气管道腐蚀检测研究,E-mail:709131750@qq.com

收稿日期: 2024-07-08

  修回日期: 2024-10-28

  录用日期: 2024-10-29

  网络出版日期: 2025-04-16

Characteristics of Interference Fluctuation of Different Types of Stray Currents on Pipelines

Expand
  • (1.PipeChina Institute of Science and Technology, Tianjin 300457, China;2.Tianjin Oil and Gas Transportation Branch of PipeChina Northern Pipeline Company, Tianjin 300457, China;3.Zhongyuan Natural Gas Co., Ltd.of PipeChina Northern Pipeline Company, Puyang 457001, China;4.Cangzhou Oil and Gas Transportation Branch of PipeChina Northern Pipeline Company, Cangzhou 061001, China)
XU Chengwei(1982-),Ph.D.,Senior Engineer,Research Focus:Oil and Gas Pipeline Corrosion Detection,E-mail:709131750@qq.com

Received date: 2024-07-08

  Revised date: 2024-10-28

  Accepted date: 2024-10-29

  Online published: 2025-04-16

摘要

交直流杂散电流干扰腐蚀已成为管道失效和破坏的主要原因之一,严重威胁管道运行安全。 为了全面掌握不同交直流杂散电流干扰源的特征,以及对管道阴极保护参数的影响规律,采用试片法对某输气管道不同类型的干扰源进行长期监测。 通过测试结果,分析总结了交、直流静态干扰、动态干扰及静态-动态复杂干扰等7 种干扰类型的典型干扰特征,同时针对复杂的交直流混合干扰,提出人身安全、交直流混合干扰和阀室绝缘设施相应的评价指标、阈值范围及准则和推荐方法。 研究成果为管道运行方迅速明确杂散电流干扰源类型,制定相应防护措施,减少复杂杂散电流干扰造成的管道腐蚀风险提供依据。

本文引用格式

徐承伟, 陈瑞瑞, 张荣, 夏亮, 蓝卫, 毕武喜 . 不同类型杂散电流对管道干扰波动规律特征[J]. 材料保护, 2025 , 58(3) : 155 -163 . DOI: 10.16577/j.issn.1001-1560.2025.0052

Abstract

AC/DC stray current interference corrosion has become one of the main causes of pipeline failure and damage, which seriously threatens the safety of pipeline operation.In order to understand the characteristics of different AC-DC stray current interference sources and their influence on the cathodic protection parameters of pipelines, the coupon method was used to monitor the interference sources of different types in a gas pipeline for a long time.Based on the test results, the typical interference characteristics of 7 types of interference types, including AC and DC static interference, dynamic interference and statically dynamic complex interference, were analyzed and summarized.Meanwhile, for complex AC and DC mixed interference, the corresponding evaluation indexes, threshold ranges, criteria and recommended methods were proposed for personal safety, AC and DC mixed interference and valve chamber insulation facilities.The research results provide a basis for pipeline operators to quickly identify the types of stray current interference sources, formulate corresponding protective measures, and reduce the risk of pipeline corrosion caused by complex stray current interference.