Today is Email Alert  RSS

Analysis on Corrosion Leakage Causes for Turbulator of Absorbing Tower in Certain Subcritical Units

Expand
  • 1.North China Electric Power Research Institute Co.,Ltd. 2.Sanhe Power Generation Co.,Ltd.

Received date: 2020-10-16

  Online published: 2025-07-10

Abstract

After 18 months of operation for certain subcritical units,the turbulator of absorbing tower was corroded and leaked. By means of macroscopic analysis,material composition analysis,microstructure analysis,corrosion product composition analysis and fracture morphology analysis,the cause of corrosion and leakage was analyzed. Results showed that two types of corrosion occurred in the turbulator of absorbing tower: crevice corrosion in the TP304 stainless steel part,and stress corrosion in the weld-seam of TP316L stainless steel part. Besides,the countermeasure was proposed to avoid such kinds of damage in the future.

Cite this article

SONG Zi-bo, WANG Zhi-chun, YANG Hai-song, PENG Bo . Analysis on Corrosion Leakage Causes for Turbulator of Absorbing Tower in Certain Subcritical Units[J]. Materials Protection, 2021 , 54(3) : 158 -163 . DOI: 10.16577/j.cnki.42-1215/tb.2021.03.028